1.
Radiol Phys Technol ; 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38351260

ABSTRACT

The work investigates the implementation of personalized radiotherapy boluses by means of additive manufacturing technologies. Boluses materials that are currently used need an excessive amount of human intervention which leads to reduced repeatability in terms of dosimetry. Additive manufacturing can solve this problem by eliminating the human factor in the process of fabrication. Planar boluses with fixed geometry and personalized boluses printed starting from a computed tomography scan of a radiotherapy phantom were produced. First, a dosimetric characterization study on planar bolus designs to quantify the effects of print parameters such as infill density and geometry on the radiation beam was made. Secondly, a volumetric quantification of air gap between the bolus and the skin of the patient as well as dosimetric analyses were performed. The optimization process according to the obtained dosimetric and airgap results allowed us to find a combination of parameters to have the 3D-printed bolus performing similarly to that in conventional use. These preliminary results confirm those in the relevant literature, with 3D-printed boluses showing a dosimetric performance similar to conventional boluses with the additional advantage of being perfectly conformed to the patient geometry.

2.
Radiol Med ; 129(2): 328-334, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38280971

ABSTRACT

PURPOSE: To report the results involving post-operative interventional radiotherapy (POIRT) in a homogenous cohort of patients affected by keloid and treated at a single institution with the same fractionation schedule. PATIENTS AND METHODS: Inclusion criteria were: surgery with a histopathological diagnosis of keloid, subsequent high-dose rate interventional radiotherapy (HDR-IRT)-12 Gy in 4 fractions (3 Gy/fr) twice a day-and follow-up period ≥ 24 months. RESULTS: One-hundred and two patients and a total of 135 keloids were eligible for the analyses. Median follow-up was 64 [IQR: 25-103] months. Thirty-six (26.7%) recurrences were observed, 12-months and 36-months cumulative incidence of recurrence were 20.7% (95% CI 12.2-28.5) and 23.8% (95% CI 14.9-31.7) respectively. History of spontaneous keloids (HR = 7.00, 95% CI 2.79-17.6, p < 0.001), spontaneous cheloid as keloid cause (HR = 6.97, 95% CI 2.05-23.7, p = 0.002) and sternal (HR = 10.6, 95% CI 3.08-36.8, p < 0.001), ear (HR = 6.03, 95% CI 1.71-21.3, p = 0.005) or limb (HR = 18.8, 95% CI 5.14-68.7, p < 0.001) keloid sites were significantly associated to a higher risk of recurrence. CONCLUSIONS: The findings support the use of surgery and POIRT as an effective strategy for controlling keloid relapses. Further studies should focus on determining the optimal Biologically Effective Dose and on establishing a scoring system for patient selection.


Subject(s)
Brachytherapy , Keloid , Radiosurgery , Humans , Keloid/radiotherapy , Keloid/surgery , Keloid/pathology , Brachytherapy/methods , Radiotherapy Dosage , Dose Fractionation, Radiation , Recurrence , Radiotherapy, Adjuvant , Treatment Outcome
3.
J Orthop Res ; 42(1): 148-163, 2024 01.
Article in English | MEDLINE | ID: mdl-37442638

ABSTRACT

The foot is responsible for the bodyweight transfer to the ground, while adapting to different terrains and activities. Despite this fundamental role, the knowledge about the foot bone intrinsic kinematics is still limited. The aim of the study is to provide a quantitative and systematic description of the kinematics of all bones in the foot, considering the full range of dorsi/plantar flexion and pronation/supination of the foot, both in weightbearing and nonweightbearing conditions. Bone kinematics was accurately reconstructed for three specimens from a series of computed tomography scans taken in weightbearing configuration. The ground inclination was imposed through a set of wedges, varying the foot orientation both in the sagittal and coronal planes; the donor body-weight was applied or removed by a cable-rig. A total of 32 scans for each foot were acquired and segmented. Bone kinematics was expressed in terms of anatomical reference systems optimized for the foot kinematic description. Results agree with previous literature where available. However, our analysis reveals that bones such as calcaneus, navicular, intermediate cuneiform, fourth and fifth metatarsal move more during foot pronation than flexion. Weightbearing significantly increase the range of motion of almost all the bone. Cuneiform and metatarsal move more due to weightbearing than in response to ground inclination, showing their role in the load-acceptance phase. The data here reported represent a step toward a deeper understanding of the foot behavior, that may help in the definition of better treatment and medical devices, as well as new biomechanical model of the foot.


Subject(s)
Calcaneus , Metatarsal Bones , Biomechanical Phenomena , Foot/physiology , Weight-Bearing/physiology
4.
Curr Oncol ; 30(9): 7926-7935, 2023 08 28.
Article in English | MEDLINE | ID: mdl-37754491

ABSTRACT

In this technical development report, we present the strategic placement of fiducial markers within the prostate under the guidance of computed tomography (CT) and electromagnetic navigation (EMN) for the delivery of ultra-hypofractionated cyberknife (CK) therapy in a patient with localized prostate cancer (PCa) who had previously undergone chemo-radiotherapy for rectal cancer and subsequent abdominoperineal resection due to local recurrence. The patient was positioned in a prone position with a pillow under the pelvis to facilitate access, and an electromagnetic fiducial marker was placed on the patient's skin to establish a stable position. CT scans were performed to plan the procedure, mark virtual points, and simulate the needle trajectory using the navigation system. Local anesthesia was administered, and a 21G needle was used to place the fiducial markers according to the navigation system information. A confirmatory CT scan was obtained to ensure proper positioning. The implantation procedure was safe, without any acute side effects such as pain, hematuria, dysuria, or hematospermia. Our report highlights the ability to use EMN systems to virtually navigate within a pre-acquired imaging dataset in the interventional room, allowing for non-conventional approaches and potentially revolutionizing fiducial marker positioning, offering new perspectives for PCa treatment in selected cases.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Male , Humans , Fiducial Markers , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Tomography, X-Ray Computed , Computers , Electromagnetic Phenomena
5.
Radiother Oncol ; 178: 109424, 2023 01.
Article in English | MEDLINE | ID: mdl-36435336

ABSTRACT

BACKGROUND AND PURPOSE: Radiomics enables the mining of quantitative features from medical images. The influence of the radiomic feature extraction software on the final performance of models is still a poorly understood topic. This study aimed to investigate the ability of radiomic features extracted by two different radiomic platforms to predict clinical outcomes in patients treated with radiosurgery for brain metastases from non-small cell lung cancer. We developed models integrating pre-treatment magnetic resonance imaging (MRI)-derived radiomic features and clinical data. MATERIALS AND METHODS: Pre-radiotherapy gadolinium enhanced axial T1-weighted MRI scans were used. MRI images were re-sampled, intensity-shifted, and histogram-matched before radiomic extraction by means of two different platforms (PyRadiomics and SOPHiA Radiomics). We adopted LASSO Cox regression models for multivariable analyses by creating radiomic, clinical, and combined models using three survival clinical endpoints (local control, distant progression, and overall survival). The statistical analysis was repeated 50 times with different random seeds and the median concordance index was used as performance metric of the models. RESULTS: We analysed 276 metastases from 148 patients. The use of the two platforms resulted in differences in both the quality and the number of extractable features. That led to mismatches in terms of end-to-end performance, statistical significance of radiomic scores, and clinical covariates found significant in combined models. CONCLUSION: This study shed new light on how extracting radiomic features from the same images using two different platforms could yield several discrepancies. That may lead to acute consequences on drawing conclusions, comparing results across the literature, and translating radiomics into clinical practice.


Subject(s)
Brain Neoplasms , Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Radiosurgery , Humans , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Lung Neoplasms/etiology , Radiosurgery/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Retrospective Studies
7.
Sci Rep ; 12(1): 16900, 2022 10 07.
Article in English | MEDLINE | ID: mdl-36207422

ABSTRACT

Cone-beam CT (CBCT) scans now enable accurate measurements on foot skeletal structures with the advantage of observing these in 3D and in weight-bearing. Among the most common skeletal deformities, the varus/valgus of the hindfoot is the most complex to be represented, and a number of measure proposals have been published. This study aims to analyze and to compare these measurements from CBCT scans in a real clinical population with large such deformity. Ten patients with severe acquired adult flatfoot and indication for surgery underwent CBCT scans (Carestream, USA) while standing on that leg, before and after surgical correction. Corresponding 3D shape of each bone of the distal shank and hindfoot were defined (Materialise, Belgium). Six different techniques from the literature were used to calculate the varus/valgus deformity, i.e. the inclination of the hindfoot in the frontal plane of the shank. Standard clinical measurements by goniometers were taken for comparison. According to these techniques, and starting from a careful 3D reconstruction of the relevant foot skeletal structures, a large spectrum of measurements was found to represent the same hindfoot alignment angle. Most of them were very different from the traditional clinical measures. The assessment of the pre-operative valgus deformity and of the corresponding post-operative correction varied considerably. CBCT finally allows 3D assessment of foot deformities in weight-bearing. Measurements from the different available techniques do not compare well, as they are based on very different approaches. It is recommended to be aware of the anatomical and functional concepts behind these techniques before clinical and surgical conclusions.


Subject(s)
Flatfoot , Foot Deformities , Adult , Cone-Beam Computed Tomography , Flatfoot/diagnostic imaging , Flatfoot/surgery , Foot/diagnostic imaging , Humans , Weight-Bearing
8.
Biology (Basel) ; 11(7)2022 Jul 19.
Article in English | MEDLINE | ID: mdl-36101455

ABSTRACT

Fibular metric variations have revealed their potential in distinguishing between males and females; however the fibula remains scarcely analyzed in studies of sexual dimorphism. This work aims at investigating sexually dimorphic features in fibular proximal and distal epiphyses through geometric morphometrics methods. A total of 136 left fibulae, from two Italian and one South African identified skeletal collections were virtually acquired through CT and laser scanning and analyzed using geometric morphometric methods. Statistical analyses were performed on shape, form, and size variables. Results show that fibular epiphyses are smaller with narrower articular surfaces in females than in males in both extremities. Relevant sexual differences emerge in fibular form and size for the two Italian samples but not for the South African one, likely for its small sample size. Discriminant analysis on form principal components (PCs) offers accuracy above 80% when the samples are pooled, and reaches accuracy of 80-93% when the Italian samples are considered separately. However, our method on form PCs was not successful for the South African sample (50-53% accuracy), possibly due to the small sample size. These results show relevant morphological variation in relation to fibular form and size, with a degree of accuracy that indicates the utility of the present method for sexing human fibulae in both forensic and bioarchaeological contexts for Italian samples.

9.
J Anat ; 241(3): 667-682, 2022 09.
Article in English | MEDLINE | ID: mdl-35751880

ABSTRACT

This work aims to test accuracy and comparability of 3D models of human skeletal fibulae generated by clinical CT and laser scanner virtual acquisitions. Mesh topology, segmentation and smoothing protocols were tested to assess variation among meshes generated with different scanning methods and procedures, and to evaluate meshes-interchangeability in 3D geometric morphometric analysis. A sample of 13 left human fibulae were scanned separately with Revolution Discovery CT dual energy (0.625 mm resolution) and ARTEC Space Spider 3D structured light laser scanner (0.1 mm resolution). Different segmentation methods, including half-maximum height (HMH) and MIA-clustering protocols, were compared to their high-resolution standard generated with laser-scanner by calculating topological surface deviations. Different smoothing algorithms were also evaluated, such as Laplacian and Taubin smoothing. A total of 142 semilandmarks were used to capture the shape of both proximal and distal fibular epiphyses. After Generalized Procrustes superimposition, the Procrustes coordinates of the proximal and distal fibular epiphyses were used separately to assess variation due to scanning methods and the operator error. Smoothing algorithms at low iteration do not provide significant variation among reconstructions, but segmentation protocol may influence final mesh quality (0.09-0.24 mm). Mean deviation among CT-generated meshes that were segmented with MIA-clustering protocol, and laser scanner-generated ones, is optimal (0.42 mm, ranging 0.35-0.56 mm). Principal component analysis reveals that homologous samples scanned with the two methods cluster together for both the proximal and distal fibular epiphyses. Similarly, Procrustes ANOVA reveals no shape differences between scanning methods and replicates, and only 1.38-1.43% of shape variation is due to scanning device. Topological similarities support the comparability of CT- and laser scanner-generated meshes and validate its simultaneous use in shape analysis with potential clinical relevance. We precautionarily suggest that dedicated trials should be performed in each study when merging different data sources prior to analyses.


Subject(s)
Musculoskeletal System , Tomography, X-Ray Computed , Algorithms , Fibula , Humans , Imaging, Three-Dimensional/methods , Lasers
10.
Gait Posture ; 94: 144-152, 2022 05.
Article in English | MEDLINE | ID: mdl-35334334

ABSTRACT

BACKGROUND: A fully personalised combination of Gait Analysis (GA), including Ground Reaction Force (GRF), and patient-specific knee joint morphology has not yet been reported. This can provide valuable biomechanical insight in normal and pathological conditions. Abnormal knee varus results in medial knee condylar hyper-compression and osteoarthritis, which can be prevented by restoring proper condylar load distribution via High Tibial Osteotomy (HTO). RESEARCH QUESTION: This study was aimed at reporting on an original methodology, merging GA, GRF and Computer-Tomography (CT) to depict a patient-specific representation of the knee mechanical condition during locomotion. It was hypothesised that HTO results in a lateralized pattern of GRF with respect to the tibial plateau. METHODS: Four patients selected for HTO received clinical, radiological and instrumental examinations, pre- and post-operatively at 6-month follow-up. GA was performed during level walking and more demanding motor tasks using a 9-camera motion-capture system, combined with two force platforms, and an established protocol. Additional skin markers were positioned around the tibial-plateau rim. Weight-bearing CT scans of the knee were collected while still wearing these markers. Proximal tibial and marker morphological models were reconstructed. The markers from CT reconstruction were then registered to the corresponding trajectories as tracked by GA data. Resulting registration matrices were used to report GRF vectors on the plane best matching the tibial-plateau model and the intersection paths were calculated. RESULTS AND SIGNIFICANCE: The registration procedure was successfully executed, with a max registration error of about 3 mm. GRF intersection paths were found medially to the tibial plateau pre-op, and lateralized post-op, thus much closer to the knee centre, as expected after HTO. The exploitation of the present methodology offers personalised quantification of the original mechanical misalignment and of the effect of surgical correction which could enhance diagnostics and planning of HTO as well as other knee treatments.


Subject(s)
Osteoarthritis, Knee , Gait Analysis , Humans , Knee Joint/surgery , Osteoarthritis, Knee/diagnosis , Osteoarthritis, Knee/surgery , Osteotomy/methods , Tibia/surgery
11.
Diagnostics (Basel) ; 13(1)2022 Dec 23.
Article in English | MEDLINE | ID: mdl-36611342

ABSTRACT

Metal components of hip prostheses cause severe artifacts in CT images, influencing diagnostic accuracy. Metal artifact reduction (MAR) software and virtual monoenergetic reconstructions on dual-energy CT (DECT) systems are possible solutions that should be considered. In this study, we created a customized adjustable phantom to quantify the severity of artifacts on periprosthetic tissues (cortical and spongious bone, soft tissues) for hip prostheses. The severity of artifacts was classified by different thresholds of deviation from the CT numbers for reference objects not affected by artifacts. The in vitro setup was applied on four unilateral and three bilateral configurations of hip prostheses (made of titanium, cobalt, and stainless steel alloys) with a DECT system, changing the energy of virtual monoenergetic reconstructions, with and without MAR. The impact of these tools on the severity of artifacts was scored, looking for the best scan conditions for the different configurations. For titanium prostheses, the reconstruction at 110 keV, without MAR, always minimized the artifacts. For cobalt and stainless-steel prostheses, MAR should always be applied, while monoenergetic reconstruction alone did not show clear advantages. The available tools for reducing metal artifacts must therefore be applied depending on the examined prosthetic configuration.

12.
J Foot Ankle Res ; 14(1): 66, 2021 Dec 20.
Article in English | MEDLINE | ID: mdl-34930383

ABSTRACT

BACKGROUND: A complete definition of anatomical reference systems (ARS) for all bones of the foot and ankle complex is lacking. Using a morphological approach, we propose new ARS for these bones with the aim of being highly repeatable, consistent among individuals, clinically interpretable, and also suited for a sound kinematic description. METHODS: Three specimens from healthy donors and three patients with flat feet were scanned in weight-bearing CT. The foot bones were segmented and ARS defined according to the proposed approach. To assess repeatability, intra class coefficients (ICC) were computed both intra- and inter-operator. Consistency was evaluated as the mean of the standard deviations of the ARS position and orientation, both within normal and flat feet. Clinical interpretability was evaluated by providing a quantification of the curvature variation in the medial-longitudinal and transverse arches and computing the Djiann-Annonier angle for normal and flat feet from these new ARS axes. To test the capability to also provide a sound description of the foot kinematics, the alignment between mean helical axes (MHA) and ARS axes was quantified. RESULTS: ICC was 0.99 both inter- and intra-operator. Rotational consistency was 4.7 ± 3.5 ° and 6.2 ± 4.4° for the normal and flat feet, respectively; translational consistency was 4.4 ± 4.0 mm and 5.4 ± 2.9 mm for the normal and flat feet, respectively. In both these cases, the consistency was better than what was achieved by using principal axes of inertia. Curvature variation in the arches were well described and the measurements of the Djiann-Annoier angles from both normal and flat feet matched corresponding clinical observations. The angle between tibio-talar MHA and ARS mediolateral axis in the talus was 12.3 ± 6.0, while the angle between talo-calcaneal MHA and ARS anteroposterior axis in the calcaneus was 17.2 ± 5.6, suggesting good capability to represent joint kinematics. CONCLUSIONS: The proposed ARS definitions are robust and provide a solid base for the 3-dimensional description of posture and motion of the foot and ankle complex from medical imaging.


Subject(s)
Calcaneus , Talus , Ankle , Ankle Joint/diagnostic imaging , Calcaneus/diagnostic imaging , Humans , Lower Extremity
13.
J Biomech ; 128: 110711, 2021 11 09.
Article in English | MEDLINE | ID: mdl-34481280

ABSTRACT

Static and dynamic measurements of the medial longitudinal arch (MLA) in the foot are critical across different clinical and biomechanical research fields. While MLA deformation can be estimated using skin-markers for gait analysis, the current understanding of the correlates between skin-marker based models and radiographic measures of the MLA is limited. This study aimed at assessing the correlation and accuracy of skin-marker based measures of MLA deformation with respect to standard clinical X-ray based measures, used as reference. 20 asymptomatic subjects without morphological alterations of the foot volunteered in the study. A lateral X-ray of the right foot of each subject was taken in monopodalic upright posture with and without a metatarsophalangeal-joint dorsiflexing wedge. MLA angle was estimated in the two foot postures and during gait using 16 skin-marker based models, which were established according to the marker set of a validated multi-segment foot kinematic protocol. The error of each model in tracking MLA deformation was assessed and correlated with respect to standard radiographic measurements. Estimation of MLA deformation was highly affected by the skin-marker models. Skin-marker models using the marker on the navicular tuberosity as apex of the MLA angle showed the smallest errors (about 2 deg) and the largest correlations (R = 0.64-0.65; p < 0.05) with respect to the radiographic measurements. According to the outcome of this study, skin-marker based definitions of the MLA angle using the navicular tuberosity as apex of the arch may provide a more accurate estimation of MLA deformation with respect to that from radiographic measures.


Subject(s)
Foot , Tarsal Bones , Biomechanical Phenomena , Foot/diagnostic imaging , Gait , Humans , Posture
14.
Eur J Radiol ; 143: 109906, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34479125

ABSTRACT

PURPOSE: To systematically review and assess the methodological quality of guidelines for radiation protection in interventional radiology. MATERIALS AND METHODS: On April 15th, 2021, a systematic search for guidelines on radiation protection in interventional radiology was performed using MEDLINE, EMBASE, National Guideline Clearinghouse, and National Institute for Health and Clinical Excellence databases. Among retrieved guidelines, we then excluded those not primarily focused on radiation protection or on interventional radiology. Authors' professional role and year of publication were recorded for each included guideline. Guideline quality evaluation was performed independently by three authors using the six-domain tool "AGREE II", with an overall guideline quality score divided into three classes: low (<60%), acceptable (60-80%), and good quality (>80%). RESULTS: Our literature search identified 106 citations: after applying exclusion criteria, 11 guidelines published between 2009 and 2018 were included, most of their authors being interventional radiologists (168/224, 75%). Overall quality of included guidelines was acceptable (median 72%, interquartile range 64-83%), with only one guideline (9%) with overall low quality and four guidelines (36%) with overall good quality. Among AGREE II domains, "Scope and Purpose", "Clarity of Presentations", and "Editorial Independence" had the best results (87%, 76%, and 75% respectively), while "Applicability", "Rigor of Development", and "Stakeholder Involvement" the worst (46%, 49%, and 52% respectively). CONCLUSION: Considering all guidelines, the overall methodological quality was acceptable with one third of them reaching the highest score class. The "Applicability" domain had the lowest median score, highlighting a practical implementation gap to be addressed by future guidelines.


Subject(s)
Practice Guidelines as Topic , Radiation Protection , Radiology, Interventional , Databases, Factual , Humans , Radiologists
15.
Sci Rep ; 11(1): 16139, 2021 08 09.
Article in English | MEDLINE | ID: mdl-34373546

ABSTRACT

Acquired adult flatfoot is a frequent deformity which implies multiple, complex and combined 3D modifications of the foot skeletal structure. The difficult thorough evaluation of the degree of severity pre-op and the corresponding assessment post-op can now be overcome by cone-beam (CBCT) technology, which can provide access to the 3D skeletal structure in weight-bearing. This study aims to report flatfoot deformities originally in 3D and in weight-bearing, with measurements taken using two different bone segmentation techniques. 21 such patients, with indication for surgical corrections, underwent CBCT (Carestream, US) while standing on one leg. From these scans, 3D models of each bone of the foot were reconstructed by using two different state-of-the-art segmentation tools: a semi-automatic (Mimics Innovation Suite, Materialise, Belgium), and an automatic (Bonelogic Ortho Foot and Ankle, Disior, Finland). From both reconstructed models, Principal Component Analysis was used to define anatomical reference frames, and original foot and ankle angles and other parameters were calculated mostly based on the longitudinal axis of the bones, in anatomical plane projections and in 3D. Both bone model reconstructions revealed a considerable valgus of the calcareous, plantarflexion and internal rotation of the talus, and typical Meary's angles in the lateral and transverse plane projections. The mean difference from these angles between semi-automatic and automatic segmentations was larger than 3.5 degrees for only 3 of the 32 measurements, and a large number of these differences were not statistically significant. CBCT and the present techniques for bone shape reconstruction finally provide a novel and valuable 3D assessment of complex foot deformities in weight-bearing, eliminating previous limitations associated to unloaded feet and bidimensional measures. Corresponding measurements on the bone models from the two segmentation tools compared well. Other more representative measurements can be defined in the future using CBCT and these techniques.

16.
J Contemp Brachytherapy ; 13(3): 338-346, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34122575

ABSTRACT

Soft tissue sarcomas of the foot are extremely rare and can therefore be misdiagnosed as benign diseases, and be prematurely removed with an unplanned excision. The standard treatment is a wide local excision with an addition of radiotherapy as an alternative to a radical resection (e.g., below-knee or foot amputation). We report on a patient with primary malignant peripheral nerve sheath tumor in the foot plantar soft tissue, who had no evidence of the disease and no severe late toxicity higher than grade 2, 40 months after receiving amputation of toes and adjuvant interstitial high-dose-rate brachytherapy (HDR-BT). To the best of our knowledge, only a few cases were treated with HDR-BT with this scenario. From our findings, HDR-BT could be a safe and quick treatment option for these types of lesions.

17.
Front Bioeng Biotechnol ; 9: 613616, 2021.
Article in English | MEDLINE | ID: mdl-34026738

ABSTRACT

It is established that human movements in the vicinity of a permanent static magnetic field, such as those in magnetic resonance imaging (MRI) scanners induce electric fields in the human body; this raises potential severe risks of health to radiographers and cleaners exposed routinely to these fields in MRI rooms. The relevant directives and parameters, however, are based on theoretical models, and accurate studies on the simulation of the effects based on human movement data obtained in real conditions are still lacking. Two radiographers and one cleaner, familiar with MRI room activities and these directives, were gait analyzed during the execution of routine job motor tasks at different velocities. Full body motion was recorded in a gait laboratory arranged to reproduce the workspace of a room with an MRI full-body scanner. Body segments were tracked with clusters of at least three markers, from which position and velocity of the centroids were calculated. These were used as input in an established computer physical model able to map the stray field in an MRI room. The spatial peak values of the calculated electric field induced by motion of the head and of the entire body during these tasks, for both the health and sensory effects, were found smaller than the thresholds recommended by the European directives, for both 1.5 T and 3.0 T MRI. These tasks therefore seem to guarantee the safety of MRI room operators according to current professional good practice for exposure risks. Physical modeling and experimental measures of human motion can also support occupational medicine.

18.
Radiol Med ; 126(6): 869-877, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33660189

ABSTRACT

PURPOSE: To compare weight-bearing cone-beam computer tomography (CBCT) and conventional computer tomography (CT)-based measurements of patellofemoral alignment and stability in patients surgically treated for recurrent patellar dislocation. These scans implied respectively single-leg up-right posture, the knee flexed, and lower limb muscles activation, versus supine position with the knee extended. METHODS: A total of 17 patients (11 males/6 females) after surgical reconstruction with fascia lata allograft for recurrent patellofemoral dislocation were analyzed at 60-month follow-up. Tilt and congruence angles and tibial tuberosity-trochlear groove (TT-TG) offset were measured on images obtained from CBCT and conventional CT scans by three independent and expert radiologists. Paired t tests were performed to compare measurements obtained from the two scans. Inter-rater reliability was assessed using a two-way mixed-effects model intra-class correlation coefficient (ICC). RESULTS: Only TT-TG offset was found significantly smaller (p < 0.001) in CBCT (mean 9.9 ± 5.3 mm) than in conventional CT (mean 15.9 ± 4.9 mm) scans. ICC for tilt and congruence angles and for TT-TG offset ranged between 0.80-0.94 with measurements in CBCT scans, between 0.52 and0.78 in conventional CT. CONCLUSION: In patients surgically treated for recurrent patellar dislocation, TT-TG offset was found overestimated with conventional CT. All measurements of patellofemoral stability and alignment were found more consistent when obtained with weight-bearing CBCT compared to conventional CT.


Subject(s)
Cone-Beam Computed Tomography/methods , Orthopedic Procedures/methods , Patellar Dislocation/physiopathology , Patellofemoral Joint/physiopathology , Weight-Bearing/physiology , Adolescent , Adult , Female , Follow-Up Studies , Humans , Male , Patellar Dislocation/surgery , Patellofemoral Joint/diagnostic imaging , Postoperative Period , Range of Motion, Articular/physiology , Reproducibility of Results , Retrospective Studies , Time Factors , Young Adult
19.
J Knee Surg ; 34(9): 1014-1025, 2021 Jul.
Article in English | MEDLINE | ID: mdl-32074653

ABSTRACT

The aim of this study was to analyze the extent to which postoperative patellofemoral joint (PFJ) kinematics assessed at 6-month follow-up after total knee arthroplasty (TKA) mimics the intraoperative kinematics after final component implantation. The study hypothesis, already proved in terms of tibiofemoral joint (TFJ) kinematics, is that the intraoperative assessment of PFJ kinematics after component implantation is also capable of predicting postoperative knee kinematics during activities of daily living. Twenty patients selected for TKA with patellar resurfacing were implanted using surgical navigation, including patellar component positioning via a novel computer-assisted procedure. This allowed for intraoperative TFJ and PFJ kinematic assessment after final component implantation. At 6-month follow-up, all patients were contacted for follow-up control; in addition to clinical examination, this implied postoperative kinematics assessments by three-dimensional video fluoroscopy of the replaced knee during standard activities of daily living. Several traditional PFJ, as well as TFJ, rotations and translations were calculated intra- and postoperatively and then statistically compared. Good postoperative replication of the intraoperative measurements was observed for most of PFJ variables analyzed, as well as those for TFJ. Relevant statistical analysis also supported the significant consistency between the intra- and postoperative measurements. Pertaining to the present findings on a statistical basis, intraoperative measurements performed at both TFJ and PFJ kinematics using a surgical navigation system under passive conditions, are predictive of the overall knee kinematics experienced at postoperative follow-ups by the same replaced knees in typical activities of daily living.


Subject(s)
Arthroplasty, Replacement, Knee , Patellofemoral Joint , Activities of Daily Living , Biomechanical Phenomena , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/surgery , Range of Motion, Articular
20.
Foot Ankle Surg ; 27(2): 168-174, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32370949

ABSTRACT

BACKGROUND: For the diagnosis and treatment of foot and ankle disorders, objective quantification of the absolute and relative orientation angles is necessary. The present work aims at assessing novel techniques for 3D measures of foot bone angles from current Cone-Beam technology. METHODS: A normal foot was scanned via weight-bearing CT and 3D-model of each bone was obtained. Principal Component Analysis, landmark-based and mid-diaphyseal axes were exploited to obtain bone anatomical references. Absolute and relative angles between calcaneus and first metatarsal bone were calculated both in 3D and in a simulated sagittal projections. The effects of malpositioning were also investigated via rotations of the entire foot model. RESULTS: Large angle variations were found between the different definitions. For the 3D relative orientation, variations larger than 10 degrees were found. Foot malposition in axial rotation or in varus/valgus can result in errors larger than 5 and 3 degrees, respectively. CONCLUSIONS: New measures of foot bone orientation are possible in 3D and in weight-bearing, removing operator variability and the effects of foot positioning.


Subject(s)
Cone-Beam Computed Tomography , Foot Bones/diagnostic imaging , Imaging, Three-Dimensional , Patient-Specific Modeling , Weight-Bearing , Calcaneus , Humans , Male , Metatarsal Bones , Young Adult